By Saad Iqbal
Your pump pressure gauge just read 1,100 psi higher than your pre-job model said it would, and the control van is asking why. You check the fluid density, the nozzle, the BHA — everything matches. The number that’s wrong is the one nobody double-checked by hand: friction pressure in the coiled tubing string itself, bent around a 72-inch reel at a curvature that standard pipe-flow equations were never built to handle. Get that number wrong on a deep intervention and you either rig up a pump that can’t hit surface pressure, or you blow through your tubing’s pressure rating mid-job.
This tutorial walks through the full Darcy-Weisbach calculation for coiled tubing (CT) friction pressure — velocity, Reynolds number, the Swamee-Jain friction factor, and the curvature correction that straight-pipe hydraulics textbooks skip — then automates it in Python so you’re not re-deriving it on a laptop at the wellsite.
Why does coiled tubing need its own friction model?
Straight-pipe Darcy-Weisbach assumes a fluid particle travels in a straight line down the pipe axis. On a coiled tubing reel, it doesn’t — it spirals. That secondary (Dean) flow adds a rotational velocity component on top of the axial one, which increases wall shear and friction loss beyond what a straight-pipe calculation predicts. It also shifts the laminar-to-turbulent transition to a higher Reynolds number, because the curvature stabilizes the flow. Ignore both effects and you’ll under-predict pump pressure on every job that uses a tight reel radius.
The two numbers that capture this are the curvature ratio and the curvature-corrected critical Reynolds number, both covered in Steps 2 and 4 below.
Prerequisites
Before you start, have these on hand:
- Pump rate Q (bpm) and fluid density ρ (ppg) and viscosity μ (cP) — from your fluids program or lab report.
- Coiled tubing OD/ID (in) and string length L (ft) — from the tubing tally.
- Reel core diameter Dreel (in) — from the unit spec sheet (a typical CT reel core is 60–90 in).
- A basic grasp of Reynolds number and the Darcy-Weisbach pressure-drop equation.
- Python 3 installed if you want to run Step 5’s automation (a Jupyter notebook works well for this).
Worked example used throughout: Q = 2.0 bpm, ρ = 8.34 ppg (fresh water), μ = 1.0 cP, CT ID = 1.688 in, L = 10,000 ft, Dreel = 72 in.
One tally note before you start: CT ID isn’t a single number for the whole string. A tapered string is built from spools of different wall thickness — heavier wall near surface, lighter wall downhole — so a 2.0-in OD string might run 1.688 in ID in its thinnest section and noticeably less in its thickest. Pull the ID for the specific section you’re modeling (usually the thinnest-wall, highest-velocity section, since that’s where friction loss concentrates) rather than a single string-average figure from the tally header.
Step 1 — Calculate fluid velocity inside the coiled tubing
Convert your pump rate to a velocity inside the CT bore. In oilfield units:
v (ft/s) = 0.408 * Q (bpm) / D^2 (in)
Why it matters: every downstream term — Reynolds number, friction factor, pressure drop — scales with velocity squared or worse. A transcription error here (using OD instead of ID is the classic one) throws off the entire pressure prediction.
Worked: v = 0.408 × 2.0 / 1.688² = 12.04 ft/s.

Step 2 — Calculate the Reynolds number and the curvature ratio
Reynolds number tells you whether the flow is laminar or turbulent:
Re = 928 * rho (ppg) * v (ft/s) * D (in) / mu (cP)
Then compute the curvature ratio, which quantifies how tightly the string is bent relative to its own diameter:
kappa = d / D_reel
Why it matters: a straight-pipe Reynolds number of ~157,000 looks comfortably turbulent, but coiled tubing’s transition point moves — you need both numbers before you can trust any friction-factor correlation in Step 3.
Worked: Re = 928 × 8.34 × 12.04 × 1.688 / 1.0 = 157,341 (turbulent). κ = 1.688 / 72 = 0.0234.

Step 3 — Solve the Darcy friction factor with Swamee-Jain
For turbulent flow, use the explicit Swamee-Jain correlation instead of iterating Colebrook-White by hand:
f_darcy = 0.25 / [ log10( (e/D)/3.7 + 5.74/Re^0.9 ) ]^2
where e is absolute pipe roughness (use ~0.0006 in for new coiled tubing, or your tubing manufacturer’s value).
Why it matters: Swamee-Jain is accurate to within about 1% of the implicit Colebrook-White equation across the full turbulent range, so you get Colebrook-grade accuracy without a root-finding loop — important if you’re doing this by hand on location.
Worked: fDarcy = 0.02178.

Step 4 — Apply the Darcy-Weisbach equation, then correct for curvature
First, calculate the straight-pipe pressure drop in field units:
dP_straight (psi) = f_Fanning * L (ft) * rho (ppg) * v^2 (ft/s) / (25.8 * D (in))
where f_Fanning = f_Darcy / 4
Then apply the curvature uplift. Based on the Srinivasan et al. (1970) correlation for the coil-curvature effect on friction, a widely used field approximation adds roughly 10–15% to the straight-pipe pressure drop for typical CT reel curvature ratios; this tutorial uses +12% as a representative mid-range value — always confirm the uplift percentage your own tubing vendor or hydraulics software recommends for your specific reel geometry, since it is sensitive to κ.
dP_CT = dP_straight * 1.12
Why it matters: this is the step most CT friction calculators silently skip, because they’re built on generic pipe-flow libraries. Skipping it is exactly what produces the kind of pump-pressure surprise described at the top of this article. The uplift isn’t a flat constant across all jobs either — a tighter reel (smaller Dreel relative to tubing OD, i.e. a larger κ) pushes the correction toward the high end of that 10–15% band, while a larger reel on the same tubing size sits toward the low end. If you’re running the same tubing on two different units with different reel cores, don’t assume last job’s uplift percentage carries over unchanged.
Worked: dPstraight = 1,512.1 psi. dPCT = 1,512.1 × 1.12 = 1,693.6 psi.

Step 5 — Automate it in Python
Once the hand calculation checks out, wrap it in a function so you can run sensitivity cases (different rates, fluids, reel sizes) in seconds instead of re-deriving the arithmetic each time.
import math
def ct_friction_pressure(Q_bpm, rho_ppg, mu_cP, id_in, L_ft, reel_in,
roughness_in=0.0006, curvature_uplift=1.12):
v_fts = 0.408 * Q_bpm / id_in**2
Re = 928 * rho_ppg * v_fts * id_in / mu_cP
kappa = id_in / reel_in
Re_crit_ct = 2100 * (1 + 12 * kappa**0.5)
if Re < Re_crit_ct:
f_darcy = 64 / Re
else:
f_darcy = 0.25 / (math.log10(
(roughness_in / id_in) / 3.7 + 5.74 / Re**0.9
))**2
f_fanning = f_darcy / 4
dp_straight = f_fanning * L_ft * rho_ppg * v_fts**2 / (25.8 * id_in)
dp_ct = dp_straight * curvature_uplift
return {
"velocity_ft_s": round(v_fts, 2),
"reynolds_number": round(Re, 0),
"critical_reynolds_ct": round(Re_crit_ct, 0),
"flow_regime": "turbulent" if Re >= Re_crit_ct else "laminar",
"dp_straight_psi": round(dp_straight, 1),
"dp_ct_corrected_psi": round(dp_ct, 1),
}
result = ct_friction_pressure(2.0, 8.34, 1.0, 1.688, 10_000, 72)
print(result)
# {'velocity_ft_s': 12.04, 'reynolds_number': 157341.0,
# 'critical_reynolds_ct': 5959.0, 'flow_regime': 'turbulent',
# 'dp_straight_psi': 1512.1, 'dp_ct_corrected_psi': 1693.6}
Why it matters: the function checks flow regime automatically via the curvature-corrected critical Reynolds number, so it won’t silently apply a turbulent correlation to a laminar case — a mistake that’s easy to make when you’re copying a spreadsheet formula down a column of different rates.

Run it in a plain Python script, or interactively in a Jupyter notebook if you want to plot pressure drop against rate for several reel sizes side by side.
Expected result and sanity check
For the worked example above, you should land on a curvature-corrected friction pressure of ~1,694 psi over 10,000 ft of 1.688-in CT at 2 bpm. As a sanity check: friction pressure should scale roughly with the square of velocity (double the rate, friction pressure roughly quadruples in the turbulent regime) and linearly with string length. If your number doesn’t track that way when you perturb an input, recheck your unit conversions before you trust the result.
Common pitfalls
- Using nominal OD instead of actual ID. Coiled tubing ID changes with wall thickness grade, and wall thickness changes along a tapered string — use the ID for the specific joint/section you’re modeling, not a single string-average value.
- Skipping the curvature correction entirely. A straight-pipe Darcy-Weisbach calculation will under-predict CT friction pressure, particularly on smaller reel cores or smaller-OD tubing where κ is larger.
- Mixing unit systems mid-calculation. The field-unit constants (0.408, 928, 25.8) are only valid for the specific unit combination shown (bpm, ppg, cP, in, ft, ft/s, psi) — swap in SI units without converting the constants and you’ll get a number that looks plausible but is wrong by orders of magnitude.
- Using a surface viscosity for the whole string. Fluid viscosity drops as it heats up going downhole, which lowers friction pressure in the lower part of the string relative to a single surface-temperature value. For a long, hot well, split the calculation into surface and bottomhole segments with their own temperature-corrected viscosity rather than using one μ for the full length.
Related reading
- Coiled Tubing Lockup Prediction: Buckling Force Calculation Step by Step — for the mechanical (not hydraulic) limit on how far CT can be pushed into a well.
- Flowline Pressure Drop: Darcy-Weisbach Step by Step — the same governing equation applied to straight surface flowlines, without the curvature correction.
- Hydraulic Horsepower Sizing for a Frac Job: Pump Fleet Calculation Step by Step — for sizing the pump fleet once you know your total system pressure.